For use in both External and Internal Bracing Elements
- The Milsons Bracing Bracket has been engineered to offer premium support
with quality panel hold-down bracing elements. - Offering speedy installation, Milsons Bracing Brackets require little effort to install accurately.
- For use in external and internal bracing elements
- Exceeds NZBS 3604:2011
- Premium coated fasteners
- 2 x Bracing Brackets 95 x 70 x 55 mm
- 14 x HWF 12G x 35 mm T17 Mechanical Galvanized Screws
Milsons Bracing Brackets should be fixed using an M10 x 140 mm Galvanised Screw Bolt (not supplied in this kit).
- Concrete Slab fixing achieves the characteristic uplift strength of 15kN.
- Timber floor fixing achieves the characteristic strength of 12kN.
Installation Instructions
Preparation
- Identify the desired location for the Bracing Bracket, ensuring its fits within the wall frame.
- Position the Bracing Bracket where the bottom plate and stud meet, ensuring a snug fit to both surfaces.
- Mark the position for the Screw Bolt using the Bracing Bracket as a guide, then remove the Bracket.
- Drill a 10 mm hole to the desired depth for the Screw Bolt, cleaning out the hole of dust and debris prior to installation of the Screw Bolt.
Installation
- Place the Bracing Bracket back into position and install HWF 12G x 35 mm T17 Mechanical Galv Screws into the bottom.
- Install a 10 mm x 140 mm Screw Bolt (not included in this kit) into the pre-drilled hole.
- Install the remaining HWF 12G x 35 mm T17 Mechanical Galv Screws vertically into the upper plate.
Durability
The following table provides an easy guide for selecting Milsons product with corrosion resistant finishes that will meet and exceed NZS 3604:2011 Table 4.1. Milsons Bracing Bracket Kits are only available in Galvanised Steel.
| Zone | Fixing Fastening | Environment | Product |
|---|---|---|---|
| All Zones | Nail Plates | CLOSED – Fully enclosed walls, floors and roof spaces | Zinc Coated Z275 |
| C-Nails and Bolts | Hot-Dipped Galvanised Steel | ||
| All other structural fixings | CLOSED | Carbon Steel-Zinc Coated | |
| Zones B and C | All subfloor fastenings more than 600 mm above the ground | SHELTERED – Vented 7000 mm2/m2 or Less | Hot-Dipped Galvanised Steel |
| EXPOSED – Vented MORE than 7000 mm2/m2 | 304 Stainless Steel | ||
| All subfloor fastenings within 600 mm of the ground | SHELTERED & EXPOSED | 304 Stainless Steel | |
| All other structural fixings | SHELTERED | Hot-Dipped Galvanised Steel | |
| All other structural fixings | EXPOSED | 304 Stainless Steel | |
| Zone D | All structural fixings | SHELTERED & EXPOSED | 304 Stainless Steel |